Product description
- current measurement up to 200 A AC via open current clamp
- voltage measurement up to 1000 V AC/DC (with/ without acoustic signal), from 50 V onwards no batteries required
- LED step indicator: 12, 50, 120, 230, 400, 690, 1000 V
- precise due to TRUE RMS measuring method
- phase-sequence test via green LEDs (right/ left)
- single-pole external conductor test via red LED
- continuity test by means of red LED and buzzer
- polarity test via +/- LED
- one-hand operation for voltage measurement at sockets (19 mm)
- LED measuring point illumination
- memory of measured value (HOLD)
- measuring category CAT IV 600 V, CAT III 1000 V
- incl. belt holster, measuring leads, contact tip protection, contact tip enlargement, batteries
BENNING CM 1-4 | |
---|---|
indicating range | 9,999 (illuminated)/ LED |
basic accuracy | 1 % |
AC voltage | 6 V – 1000 V |
DC voltage | 6 V – 1000 V |
AC current | 0.1 A – 200 A |
DC current | – |
resistance | 1 Ω – 50 kΩ |
continuity / diode | yes / – |
frequency | – |
capacity | – |
effective power | – |
power factor (cos φ) | – |
interface | – |
software | – |
memory / data log | HOLD |
measuring method | TRUE RMS |
max. clamp opening | 16 mm |
measuring category | CAT III 1000 V, CAT IV 600 V |
item no. | 044686 |
Technical changes, model or color modifications, mistakes and delivery facilities without notice! No responsibility for literal mistakes.