Product description
The new TRUE RMS digital multimeter is suited for the most challenging measuring tasks in electrical trade, industry, service and HVAC technology.
- in an ergonomic and rubber-coated 2K housing
- True RMS measurement (AC, AC+DC)
- voltage measurement up to 1000 V
- current measurement up to 10 A AC/ DC and microampere range
- resistance, frequency, capacity, duty cycle, temperature, current loop
- quick continuity test
- AutoV / LoZ function
- jack control with warning
- low-pass filter
- highest measuring category CAT IV 600 V
Application
The new TRUE RMS digital multimeter in an ergonomic and rubber-coated 2K housing is suited for the most challenging measuring tasks in electrical trade, industry, service and HVAC technology.
- Electrical trade
- LoZ voltage measurement with low input impedance (> 2 kΩ) to suppress reactive voltages
- measurement of the CP control signal (duty cycle/amplitude) of EV charging stations (wall boxes) for electric vehicles (requires the BENNING EV 3-2 test adapter, item no. 044169 and adapter BNC – 4 mm jack, item no. 10231627)
- Industry
- TRUE RMS voltage and frequency measurement for frequency converter drives and loads with superimposed harmonics
- measurement of the 4 mA to 20 mA current loop signal in process technology
- Service
- AutoV function with automatic switching (AC/ DC) and measuring range selection for quick troubleshooting
- visual and acoustic continuity test with fast response time (< 100 µs) for localising defective components, cable breaks and loose terminals
- HVAC technology
- µA measuring range for measurements on flame sensors (ionisation current) and measurement of the sacrificial anode current (mA) of hot water storage tanks
- measurement of temperature and exhaust gas temperature in heating, ventilation and air conditioning systems (HVAC)
Measuring functions
- TRUE RMS voltage measurement (1000 V)
- TRUE RMS current measurement (10 A, 20 A for 30 s.)
- resistance measurement (40 MΩ)
- capacity measurement (10 mF)
- frequency measurement (mains and logic level)
- duty cycle (%)
- 4 mA to 20 mA DC current loop (%)
- temperature measurement (°C and °F)
- quick continuity test (< 100 µs) with optical and acoustic indication
- diode test
- Voltsensor function (non-contact and single-pole phase testing (2 sensitivities))
Features
- backlit digital display with a resolution of 60,000 digits
- TRUE RMS measurement (AC and AC+DC)
- MIN/MAX/average and quick PEAK recording (250 µs)
- jack control (visual/acoustic) in the µA/mA and A ranges with warning in case of operating errors (fuse protection)
- „AutoV“ function for automatic AC/DC switch-over and measuring range selection
- low-pass filter (HFR high-frequency suppression, 1000 Hz) for measurements at pulsed motor drives
- display HOLD and Auto-HOLD when the measured value is stable
- ergonomic 2-component housing for increased grip and impact resistance
Functions
- REL Δ relative measurement for offset compensation
- VoltSense (Voltsensor) non-contact and single-pole phase testing with 2 sensitivity levels
- AUTO-RANGE automatic measuring range selection for increased ease of use
- HOLD/ A-HOLD manual and automatic storage of the display value for convenient reading
- PEAK quick memory of MAX/ MIN peak value (250 µs) for current and voltage (APO disabled)
- Resistance/ continuity ( /) max. resolution 0,01 Ω up to 60 MΩ / visual and acoustic signal with fast response time (< 100 µs)
- Logic level (Hz/ %) frequency and duty cycle measurement of logic signals
- mV DC, AC, AC+DC 0.01 V resolution (600 mV measuring range)
- V DC, AC+DC 0.03 % basic accuracy VDC (max.)
- V AC/ HFR connectable low-pass filter for measurements on frequency converters and for measuring noisy signals
- AutoV automatic AC+DC switch-over and measuring range selection
- LoZ low input impedance (> 2 kΩ) to suppress reactive voltages
- Jack control (optical/ acoustic) warning in case of incorrect measuring range selection to protect the fuses
- Robust and ergonomic housing with integrated protective rubber holster, rear stand and measuring lead holder
- APO (Auto Power OFF) automatic switch-off (“APO”) after 30 min. for extended battery lifetime (can be disabled)
- Large LC display with 60 000 digit resolution and illumination, rate: 5/ s
- RANGE automatic and manual measuring range selection
- Analogue bar graph for the detection of measuring trends, rate: 50/ s
- Function / function selection and display illumination (APO, 16 min.)
- Hz measurement of noisy mains frequencies
- MIN/ MAX memory of MIN/ MAX/ AVG measurement value (APO disabled)
- 4 mA – 20 mA DC current loop measurement for process signals
- mA/ A DC, AC, AC+DC for precise current measurement (TRUE RMS)
- µA DC, AC, AC+DC measurement of low currents, e. g. ionisation current of a gas heating system (HVAC technology)
- Temperatur via K type sensor in °C and °F
- Capacity/ diode measurement of capacitors up to 10 mF, visual and acoustic diode testing
- Safety EN 61010-1, EN 61010-2-033
- CAT IV 600 V/ CAT III 1000 V transient protection up to 8 kV (1.2/50 µs)
- TRUE RMS AC, AC+DC TRUE RMS measuring method for non-sinusoidal signals
- 1 kV HBC fuses with high breaking capacity 20 kA@1000 V, F 11 A / 30 kA@1000 V, F 0,4 A
Silicone measuring leads with 2 mm and 4 mm measuring probe highly flexible measuring lead with gold-plated measuring probe (reducing oxidation) for reliable contacting