{"id":18918,"date":"2024-06-29T22:37:39","date_gmt":"2024-06-29T20:37:39","guid":{"rendered":"https:\/\/biname.be\/?post_type=product&#038;p=18918"},"modified":"2024-09-10T18:41:00","modified_gmt":"2024-09-10T16:41:00","slug":"digital-current-clamp-multimeter-benning-cm-5-1","status":"publish","type":"product","link":"https:\/\/biname.be\/fr\/shop\/product-category\/product\/digital-current-clamp-multimeter-benning-cm-5-1\/","title":{"rendered":"Digital Current-Clamp Multimeter BENNING CM 5-1"},"content":{"rendered":"<ul>\n<li>automatic selection of the correct measuring function for TRUE RMS voltage\/current (AC \/ DC), resistance, continuity and diode test<\/li>\n<li>safe and easy operation \u2013 measuring errors due to incorrect measuring range selection are excluded<\/li>\n<li>short response time due to 5 scanning values per second<\/li>\n<li>voltage measurement with low input impedance (LoZ) to suppress capacitively\/inductively induced voltages<\/li>\n<li>multi functional and powerful by TRUE RMS measuring method\u00a0for industrial applications<\/li>\n<li>secure current measurements up to 600 A AC \/ DC<\/li>\n<li>highest measurement method CAT IV 600 V allows measurements directly at the source of low voltage installation<\/li>\n<li>LC display and background light<\/li>\n<li>compact protective case included<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-18919 size-large\" src=\"https:\/\/biname.be\/wp-content\/uploads\/2024\/06\/IMG_0528-1024x356.jpeg\" alt=\"\" width=\"980\" height=\"341\" srcset=\"https:\/\/biname.be\/wp-content\/uploads\/2024\/06\/IMG_0528-1024x356.jpeg 1024w, https:\/\/biname.be\/wp-content\/uploads\/2024\/06\/IMG_0528-600x208.jpeg 600w, https:\/\/biname.be\/wp-content\/uploads\/2024\/06\/IMG_0528-300x104.jpeg 300w, https:\/\/biname.be\/wp-content\/uploads\/2024\/06\/IMG_0528-768x267.jpeg 768w, https:\/\/biname.be\/wp-content\/uploads\/2024\/06\/IMG_0528.jpeg 1057w\" sizes=\"auto, (max-width: 980px) 100vw, 980px\" \/><\/p>\n<div class=\"overflowClass\">\n<div class=\"ce_table grid12  block\">\n<table id=\"table_23931\">\n<thead>\n<tr>\n<th class=\"head_0 col_first unsortable\"><\/th>\n<th class=\"head_1 col_last\">BENNING CM 5-1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row_0 row_first odd\">\n<th class=\"col_0 col_first\" scope=\"row\">indicating range<\/th>\n<td class=\"col_1 col_last\">9,999<\/td>\n<\/tr>\n<tr class=\"row_1 even\">\n<th class=\"col_0 col_first\" scope=\"row\">basic accuracy<\/th>\n<td class=\"col_1 col_last\">0.9 %<\/td>\n<\/tr>\n<tr class=\"row_2 odd\">\n<th class=\"col_0 col_first\" scope=\"row\">AC voltage<\/th>\n<td class=\"col_1 col_last\">1.3 V \u2013 750 V<\/td>\n<\/tr>\n<tr class=\"row_3 even\">\n<th class=\"col_0 col_first\" scope=\"row\">DC voltage<\/th>\n<td class=\"col_1 col_last\">0.7 V \u2013 1.000 V<\/td>\n<\/tr>\n<tr class=\"row_4 odd\">\n<th class=\"col_0 col_first\" scope=\"row\">AC current<\/th>\n<td class=\"col_1 col_last\">0.9 A \u2013 600 A<\/td>\n<\/tr>\n<tr class=\"row_5 even\">\n<th class=\"col_0 col_first\" scope=\"row\">DC current<\/th>\n<td class=\"col_1 col_last\">0.9 A \u2013 600 A<\/td>\n<\/tr>\n<tr class=\"row_6 odd\">\n<th class=\"col_0 col_first\" scope=\"row\">resistance<\/th>\n<td class=\"col_1 col_last\">1 \u03a9 \u2013 10 k\u03a9<\/td>\n<\/tr>\n<tr class=\"row_7 even\">\n<th class=\"col_0 col_first\" scope=\"row\">continuity \/ diode<\/th>\n<td class=\"col_1 col_last\">yes \/ yes<\/td>\n<\/tr>\n<tr class=\"row_8 odd\">\n<th class=\"col_0 col_first\" scope=\"row\">frequency<\/th>\n<td class=\"col_1 col_last\">&#8211;<\/td>\n<\/tr>\n<tr class=\"row_9 even\">\n<th class=\"col_0 col_first\" scope=\"row\">memory<\/th>\n<td class=\"col_1 col_last\">HOLD<\/td>\n<\/tr>\n<tr class=\"row_10 odd\">\n<th class=\"col_0 col_first\" scope=\"row\">measuring method<\/th>\n<td class=\"col_1 col_last\">TRUE RMS<\/td>\n<\/tr>\n<tr class=\"row_11 even\">\n<th class=\"col_0 col_first\" scope=\"row\">max. clamp opening<\/th>\n<td class=\"col_1 col_last\">35 mm<\/td>\n<\/tr>\n<tr class=\"row_12 odd\">\n<th class=\"col_0 col_first\" scope=\"row\">measuring category<\/th>\n<td class=\"col_1 col_last\">CAT IV 600 V<\/td>\n<\/tr>\n<tr class=\"row_13 row_last even\">\n<th class=\"col_0 col_first\" scope=\"row\">item no.<\/th>\n<td class=\"col_1 col_last\">044066<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"ce_text grid12  block\">\n<div class=\"text-wrapper\">\n<p>Technical changes, model or color modifications, mistakes and delivery facilities without notice! No responsibility for literal mistakes.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>automatic selection of the correct measuring function for TRUE RMS voltage\/current (AC \/ DC), resistance, continuity and diode test safe and easy operation \u2013 measuring errors due to incorrect measuring range selection are excluded short response time due to 5 &hellip;<\/p>\n","protected":false},"featured_media":18922,"template":"","meta":[],"product_cat":[6901,6905],"product_tag":[],"class_list":{"0":"post-18918","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-test-measurement","7":"product_cat-digital-current-clamp-multimeter","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/product\/18918","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/media\/18922"}],"wp:attachment":[{"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/media?parent=18918"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/product_cat?post=18918"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/biname.be\/fr\/wp-json\/wp\/v2\/product_tag?post=18918"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}